Graphic Replacement for Connection

You can generate the graphic replacement for a connection using a Generative View Style (GVS).

See Also
Creating a Logical View

You can customize generative view style parameters for connections. These parameters are shared by all structure apps. Customizing parameters in this file affects the appearance of your drawings and is an administrator's task.

For the sample GVS files, see 3DEXPERIENCE Native Apps Content Reference Guide: Samples for Drafting.

Sample XML File

In the sample XML file, generative view style parameters for slot are located at the AnyView section of beam.

UserConnection

Draw
Indicates the object is to be extracted. Yes or No
GraphicReplacement
Indicates whether to use graphic replacement. Yes or No.
ChapterName
Indicates the name of the chapter containing connection symbols within the drawing symbol.

By default value is set to UserConnection.

SymbolName
Indicates the name of the detail within the catalog to instantiate for user connection

By default value is set to Column - 2 Beam.

ReferenceScale
Indicates the scale to set the connection detail.

By default value is set to 1.0.