This describes the Probes of Machining.
You can use the Thumbnails to specify the types of clash probes.
Clash Machine
The machining probe detects a clash between a machine against other components, including
also tool versus part collision detection. The mode Interrupt is available on Clash Stock and the machine; if selected it stops the simulation when a collision is
detected. Right-click on the thumbnail to set:
- Clash Machine Detection Off
- Clash Machine Detection On
- Clash Machine Detection Stop
- Definition: Opens the Clash Machine
Definition dialog box.
See Activating the Dynamic Clash Probe.
The Clash Machine Definition dialog box allows you to specify
which clash pairs to apply. From this dialog box, you can:
- Activate or Deactivate Clash Detection Pairs
- Activate or deactivate clash detection pairs on tool parts, tool machine beds, tool
fixtures, machine head parts, machine head machine beds, machine head fixtures, and
machine head stock. You can also activate or deactivate clearance mode for each of
these parameters. If a clearance mode is activated, you can define a
Clearance value as:
- A positive value reports a message when the components come near each other
within the specified value.
- A zero value reports a message if the components come in contact.
- A negative value reports a message when the components collide within the
specified value.
Note:
When the clearance mode is activated with a positive clearance value, the
fault is reported in the Fault List as a Clearance with this specific icon . The faults can
also be filtered by clearance.
- Define Custom Clash Pairs
- Expand the Define Custom Clash Pair panel to create, modify,
or delete custom clash pairs. All custom clash pairs are listed in the list box.
- You can select to create a custom clash
pair. You can also enter a name in the Custom Clash Pair Item
field. Clicking Add
allows you to select products in the work area, Delete
removes products from the clash group. Clicking Apply saves
the custom clash pair and adds it to the list of clash pairs displayed in the dialog
box.
- Select a clash pair item from the list box to modify it. Clicking
Delete
deletes the clash pair.
- Highlight Clashing Groups
- Highlights clashing groups. To unhighlight the clashing groups, click the button
again.
- The Highlight Clashing Groups option is avaialble only for
the following machine head clash pairs:
- Part
- Machine Bed
- Fixtures
Clash Stock
Detect clashes between stock and other components, such as tools and tool holders.
Right-click on the thumbnail to set:
- Clash Stock Detection Off
- Clash Stock Detection On
- Clash Stock Detection Stop
- Definition: Opens the Clash Stock
dialog box.
The Clash Stock dialog box allows you to specify gouge and clash
volume parameters. From this dialog box, you can:
- Detect Gouge
- Select this check box to detect gouges and define the Gouge
Tolerance. The Gouge Tolerance is set to 0.05mm
by default, all gouges smaller than this value are not detected.
- All gouges are displayed in the Fault Type list, and are
sorted accordingly. For more information, see Fault Type.
- Compute Clash Volume
- Select this check box to compute the clash volume and define a minimum acceptable
gouge volume to filter false positive clash detection. The Min Acceptable
Gouge Volume is set to 0.00mm3 by default.